![]() ![]() Sidescan Waterfall Sidescan data from the multibeam. Average backscatter (one sample per sounding) or snippets (many samples). Good for visualization, targeting and comparison to sidescan. Waterfall Windows Multibeam Waterfall Color or solid TIN display.(Based on Range Settings) 3-D Seafloor Window Styles: Solid / Color TIN + Wireframe, Color Dots (Useful for Gap display) Mouse targeting and measurement. Color coding can be based on beam quality. Profile and 3-D Seafloor Profile Window Single sweep from aft looking forward.Use Device Selection to select data when there is more than one source. Use the View Menu to enable individual windows. 5 Selectable Windows 15 windows to choose from.QC: Heave drift, SV profile no longer valid (doesnt match the sensor). Typical Alarms: Devices: Timeout, COM or Network port open error, checksum error. Red = Look Out! Various system measurements updated once a second. 4 HYSWEEP Main Window Alarm Indicators Green = OK.TPU setup 3HYPACK Multibeam Training Seminar ![]() Launch Survey: Use menu or icon to run HYPACK + HYSWEEP Survey together. TPU parameters, if you required to use Total Propagated Uncertainty. Planned lines and/or matrix for navigation.